This article describes some of the techniques that are used in fault handling
software design. A typical fault handling state transition diagram is described
in detail. The article also covers several fault detection and isolation
techniques.
Fault Handling Lifecycle
The following figure describes the fault handling lifecycle of an active unit
in a redundancy pair.

- Assume that the system is running with copy-0 as active unit and copy-1 as
standby.
- When the copy-0 fails, copy-1 will detect the fault by any of the fault
detection mechanisms.
- At this point, copy-1 takes over from copy-0 and becomes active. The state
of copy-0 is marked suspect, pending diagnostics.
- The system raises an alarm, notifying the operator that the system is
working in a non-redundant configuration.
- Diagnostics are scheduled on copy-0. This includes power-on
diagnostics and hardware interface diagnostics.
- If the diagnostics on copy-0 pass, copy-0 is brought in-service as standby
unit. If the diagnostics fail, copy-0 is marked failed and the operator is
notified about the failed card.
- The operator replaces the failed card and commands the system to bring the
card in-service.
- The system schedules diagnostics on the new card to ascertain that the
card is healthy.
- Once the diagnostics pass, copy-0 is marked standby.
- The copy-0 now starts monitoring the health of copy-1 which is currently
the active copy.
- The system clears the non-redundant configuration alarm as redundancy has
been restored.
- The operator can restore the original configuration by switching over the
two copies.
Fault Detection
One of the most important aspects of fault handling is detecting a fault
immediately and isolating it to the appropriate unit as quickly as possible.
Here are some of the commonly used fault detection mechanisms.
- Sanity Monitoring: A
unit monitors the health of another unit by expecting periodic health
messages. The unit that is being monitored should check its sanity and send
the periodic health update to the monitoring unit. The monitoring unit will
report a fault if more than a specified number of successive health messages
are lost.
- Watchdog Monitoring: This is the hardware based monitoring technique to
detect hanging hardware or software modules. The system is configured with a
hardware timer that should be never allowed to timeout. The software
periodically restarts the timer under normal conditions. If the software
goes in an infinite loop or a hardware module gets stuck, the watchdog timer
would go off. This typically leads to a hardware reset of the unit and a
hardware signal to the mate unit.
- Protocol Faults: If a unit fails, all the units that are in communication
with this unit will encounter protocol faults. The protocol faults are
inherently fuzzy in nature as they may be due to a failure of any unit in
the path from the source to destination. Thus further isolation
is required to identify the faulty unit.
- In-service Diagnostics: Sometimes the
hardware modules are so designed that they allow simple diagnostic checks
even in the in-service state. These checks are non-destructive in nature so
they do not interfere with the normal functioning of the card. For example,
on a digital trunk card, in-service diagnostics may be performed on idle
channels. If a diagnostic check fails, a fault trigger is raised.
- Transient Leaky Bucket Counters: When
the hardware is in operation, many transient faults may be detected by the
system. Transient faults are typically handled by incrementing a leaky
bucket counter. If the leaky bucket counter overflows, a fault trigger
is raised. The following are few examples of transient faults.
- Spurious interrupts: If the interrupt
service routine gets called but no device is found to have raised any
interrupt, only a leaky bucket counter is incremented. The
hardware unit is suspected only if the leaky bucket counter overflows
due to spurious interrupts happening repeatedly in a short interval.
- Spurious fault triggers: As we discussed
in the fault handling lifecycle, when a fault trigger is generated the
hardware unit is suspected and diagnostics are run. If the diagnostics
pass, the unit is brought in and a leaky bucket counter is incremented.
If this sequence repeats too often, the hardware unit may be actually
faulty but the diagnostics are not exhaustive enough to detect the
hardware fault.
- Killer trunks: Due to events like
lightening, rains etc. digital trunks might frequently generate fault
triggers but may come back in-service. If this happens too frequently,
the digital trunk is marked as a "killer trunk" and is taken
out of service. This is done to avoid the system getting overloaded with
transient fault processing.
If a unit is actually faulty, many fault triggers will be generated for that
unit. The main objective of fault isolation is to correlate the fault triggers
and identify the faulty unit. If fault triggers are fuzzy in nature, the
isolation procedure involves interrogating the health of several units. For
example, if protocol fault is the only fault reported, all the units in the path
from source to destination are probed for health.
|